Height
Requirements
Mezzanine height will
determine column size. The minimum size
Conveyor Solutions generally uses is 5" square tube.
Height can also effect stairs, for example when the
mezzanine height is 12' or greater an intermediate
platform will be required by code to break up the
run of the stair.
Clear
Height: The clear height minimums
will be determined by the local code (this will
typically be 7'-0" on either level), the maximum
clear height by the owner's requirement and the
available ceiling height of the building.
Top Of Deck:
The height of the mezzanine is determined by a
combination of the clear height requirements, frame
thickness, and decking thickness. Sometimes
top of deck requirements will be specified, as in
cases where the mezzanine height is matching an
existing mezzanine or platform.
Note: Sometimes
the clear height and top of deck requirements will
dictate the framing system choice. For
example, where there is a low ceiling, the use of an
all beam system could be used to keep the frame
thickness to a minimum. When requesting a
quote please indicate if clear height or top of deck
is more critical.
Framing Thickness
C-Section w/ bridging
12-3/4"
Beam & Beam
4" - 24"
Beam & Bar Joist
12" - 36"
Joist Girder & Bar Joist
16" - 48"
Note:
Although Beams and Joists are available in smaller
and larger sizes than mentioned above, they are
rarely used in planning because they are not cost
effective.
Decking Thickness
Roof Deck
1-1/2"
Plywood/ OSB/ MR board
3/4"
Lightweight concrete
Typically 2" (3-1/2" total)
Specialty Panel
3/4" plus mil thickness of polytexture
Floor Plate
1/8"
Bar Grating
1"
|